1″ Non-Pressurized Plus Hose Kits

NP Plus (NPP) flow centers have Flo-Link double O-ring connections to allow the flow center to be easily connected to the heat pump. The NPP includes an additional insulated 3-way valve to allow the ground loop to be flushed separate from the heat pump. One of the hose kits below may be used to provide simple and flexible plumbing. Flo-Link adapters may be used if hard piping. For example, Flo-Link x 1-1/4” PVC glue adapters (part # 3425) are available for PVC schedule 80 piping to the heat pump. See Hose Kit section and Flo-Link fitting section for other options.

PNKIT CONTENTS
1181Kit Contains:
(1) 12 ft. 1" ID black hose
(2) Insulating boot
(2) Insulating boot cap
(2) 1/4" MPT PT Plug
(2) Flo-Link x 1" hose barb (flow center)
(2) Elbow, 1" MPT x 1" hose barb w/ PT port (heat pump connection)
(8) Stainless steel hose clamps
Notes:
1. For heat pumps with 3/4" connections use swivel adapter fitting PN 3731
2. Kit available without hose PN 3814
1181CV1181 hose kit with check valve at flow center connection
1347Kit Contains:
(1) 12 ft. 1" ID black hose
(3) Insulating boot
(3) Insulating boot cap
(2) 1/4" MPT PT Plug
(2) 1/4" brass plug
(1) Flo-Link x 1" hose barb (flow center)
(1) Flo-Link elbow x 1" hose barb (flow center)
(2) Elbow, 1" MPT x 1" hose barb w/ PT port (heat pump connection)
(8) Stainless steel hose clamps
Notes: Compatible with NP Plus flow centers and heat pumps with 1" FPT connections