MAGNA3

Variable Speed Insulated Pumps with Isolation Valves

Features:

  • Variable speed circulator with integrated VFD for larger installa­tions (models up to 300 GPM)
  • Wireless communication to backup pump
  • Built-in differential pressure control
  • Ready for central pump, primary-secondary, or one-pipe systems
  • 2”, 3”, and 4” connections, depending upon model
  • Ball or butterfly isolation valves included (optional check valve for two-pump primary/backup installation)
  • Dual head models (65, 80 and 100 series)
  • Powder-coated steel cabinet (40 series)
  • Foam insulation for condensation protection
  • Wall mounted for space savings

** Submittals will open in a new tab

MAGNA3 INSULATED PUMPS
ModelMounting*M3S Single Insulated PumpM3C Single Insulated Pump w/Check Valve**M3D Dual Head*** Insulated PumpM3H High Head*** Insulated PumpField Connection
40-80
(Submittal)
Wall MountedM3S040-080ACM3C040-080ACN/AM3H040-080AC2” NPT Female
M3S040-080BCM3C040-080BCN/AM3H040-080BC
40-120
(Submittal)
Wall MountedM3S040-120ACM3C040-120ACN/AM3H040-120AC
M3S040-120BCM3C040-120BCN/AM3H040-120BC
40-180
(Submittal)
Wall MountedM3S040-180ACM3C040-180ACN/AM3H040-180AC
M3S040-180BCM3C040-180BCN/AM3H040-180BC
65-120
(Submittal)
Wall MountedM3S065-120ACM3C065-120ACN/AM3H065-120AC
M3S065-120BCM3C065-120BCN/AM3H065-120BC
Floor MountedN/AN/AN/AM3H065-120BF-VL
N/AN/AN/AM3H065-120BF-VR
N/AN/AN/AM3H065-120BF-HL
N/AN/AN/AM3H065-120BF-HR
65-150
(Submittal)
Wall MountedM3S065-150BCM3C065-150BCM3D065-150BC
(Submittal)
M3H065-150BCM3S, M3C, &
M3H065-150
have 2” NPT Female M3DO65-150
have 3” ANSI Flange
Floor MountedN/AN/AM3D065-150BF
(Submittal)
M3H065-150BF-VL
N/AN/AN/AM3H065-150BF-VR
N/AN/AN/AM3H065-150BF-HL
N/AN/AN/AM3H065-150BF-HR
80-100
(Submittal)
Wall MountedM3S080-100BCN/AM3D080-100BC
(Submittal)
M3H080-100BC3” ANSI Flange
Floor MountedM3S080-100BFN/AM3D080-100BF
(Submittal)
M3H080-100BF-VL
N/AN/AM3D080-100BF-HL
(Submittal)
M3H080-100BF-VR
N/AN/AM3D080-100BF-HR
(Submittal)
M3H080-100BF-HL
N/AN/AM3H080-100BF-HR
100-120
(Submittal)
Wall MountedM3S100-120BCN/AM3D100-120BC
(Submittal)
M3H100-120BC4” ANSI Flange
Floor MountedM3S100-120BFN/AM3D100-120BF
(Submittal)
M3H100-120BF-VL
N/AN/AM3D100-120BF-HL
(Submittal)
M3H100-120BF-VR
N/AN/AM3D100-120BF-HR
(Submittal)
M3H100-120BF-HL
N/AN/AM3H100-120BF-HR
*All insulated pumps with digit 12= “C” include isolation valves and insulated cabinets, designed for wall-mounting. Larger pumps
are available with floor stand.
**Check valve required when piping two pumps in parallel. Dual head pumps include built in check valve in volute.
***M3D and M3H insulated pumps with floor stand option may be mounted vertically or horizontally.
Standard configuration for M3D is vertical. Optional configuration is horizontal (HL, HR) except M3D065-150.
M3H may be vertical (VL,VR) or horizontal (HL,HR). See flow illustrations on next page.

Magna3 Insulated Pump Flow Options: